Live demo data
Invented sample data. This page reads it from a hosted FractalEngine node over its REST API, using a read-only token held by this site's server.
Demo Site (sample data)
Fetched 2026-11-15 21:16:03 UTC. The same data as JSON: /api/demo.json- Fractals
- 2
- Petals
- 3
- Objects
- 17
- Sensor series
- 10 (970 readings)
Hierarchy
- Demo Site (sample data)
- Main Building
- Pump Hall · 7 objects
- Control Room · 4 objects
- Yard
- Yard · 6 objects
- Main Building
Objects
| Object | Kind | Status | Model | Position in metres (x, elevation, z) | Other properties |
|---|---|---|---|---|---|
| Pump P-101 | pump | running | Sample Centrifugal CF-45 | 8, 0, 6 | installed: 2019-03-14; rated_flow_lps: 45; rated_power_kw: 18.5 |
| Pump P-102 | pump | warning | Sample Centrifugal CF-45 | 8, 0, 14 | installed: 2019-03-14; rated_flow_lps: 45; rated_power_kw: 18.5 |
| Pump P-103 (standby) | pump | standby | Sample Centrifugal CF-45 | 8, 0, 22 | installed: 2021-08-02; rated_flow_lps: 45; rated_power_kw: 18.5 |
| Suction Valve V-101 | valve | open | Sample Gate Valve DN200 | 3, 0, 10 | diameter_mm: 200; installed: 2019-03-14 |
| Discharge Valve V-102 | valve | open | Sample Check Valve DN150 | 16, 0, 10 | diameter_mm: 150; installed: 2019-03-14 |
| Flow Meter FT-101 | sensor | ok | Sample Electromagnetic Flow Meter | 20, 0, 10 | installed: 2020-01-20; measures: flow_lps |
| Pressure Sensor PT-101 | sensor | ok | Sample Pressure Transmitter | 24, 0, 10 | installed: 2020-01-20; measures: pressure_kpa |
| Motor Control Centre MCC-1 | panel | ok | Sample MCC 6-way | 2, 0, 2 | installed: 2019-03-01; measures: temperature_c |
| Operator Console | workstation | ok | Sample SCADA Console | 6, 0, 5 | installed: 2022-05-10 |
| Control Room Door D-1 | door | closed | Sample Access Door | 0, 0, 4 | installed: 2019-02-15 |
| Smoke Detector SD-1 | sensor | ok | Sample Smoke Detector | 6, 0, 1.5 | installed: 2019-03-01 |
| Storage Tank T-1 | tank | in service | Sample Steel Tank 500 | 30, 0, 20 | capacity_m3: 500; installed: 2018-11-05 |
| Level Sensor LT-201 | sensor | ok | Sample Ultrasonic Level Sensor | 27, 0, 20 | installed: 2020-06-12; measures: level_pct |
| Backup Generator G-1 | generator | standby | Sample Diesel Set 60kVA | 6, 0, 24 | installed: 2019-09-30; rated_power_kva: 60 |
| Yard Gate | gate | closed | Sample Sliding Gate | 0, 0, 15 | installed: 2018-10-01 |
| Inlet Valve V-201 | valve | open | Sample Butterfly Valve DN300 | 20, 0, 4 | diameter_mm: 300; installed: 2018-11-05 |
| Weather Mast WS-1 | sensor | ok | Sample Weather Station | 36, 0, 4 | installed: 2021-03-18; measures: temperature_c |
Sensor readings
At most 60 points per seriesPump P-101
temperature_c
48.09°C
43.23 to 51.05 °C, 24 h to 2026-11-15 20:15:00 UTC
Pump P-101
vibration_mms
2.44mm/s
2.05 to 2.69 mm/s, 24 h to 2026-11-15 20:15:00 UTC
Pump P-102
temperature_c
54.3°C
44.17 to 54.3 °C, 24 h to 2026-11-15 20:15:00 UTC
Pump P-102
vibration_mms
7.09mm/s
2.15 to 7.09 mm/s, 24 h to 2026-11-15 20:15:00 UTC
Flow Meter FT-101
flow_lps
27.8L/s
13.89 to 37.33 L/s, 24 h to 2026-11-15 20:15:00 UTC
Pressure Sensor PT-101
pressure_kpa
450kPa
430 to 462 kPa, 24 h to 2026-11-15 20:15:00 UTC
Motor Control Centre MCC-1
temperature_c
26.04°C
24.93 to 27.23 °C, 24 h to 2026-11-15 20:15:00 UTC
Level Sensor LT-201
level_pct
59.29%
48.05 to 76.48 %, 24 h to 2026-11-15 20:15:00 UTC
Backup Generator G-1
temperature_c
21.56°C
18.67 to 23.09 °C, 24 h to 2026-11-15 20:15:00 UTC
Weather Mast WS-1
temperature_c
14.67°C
7.74 to 20.39 °C, 24 h to 2026-11-15 20:15:00 UTC
The REST calls behind this page
Three read-only calls with a Viewer token. Replace the host and $TOKEN with your own node and token; see the API overview.
Hierarchy
Verse, fractals, petals and nodes with their positions.
curl -H "Authorization: Bearer $TOKEN" \
https://demo-node.example/api/v1/hierarchyObject properties
The properties of every node, in one read-only query.
curl -X POST https://demo-node.example/api/v1/query \
-H "Authorization: Bearer $TOKEN" \
-H "Content-Type: application/json" \
-d '{"sql":"SELECT node_id, properties FROM node LIMIT 500"}'Sensor readings
The newest readings, which this page groups per sensor.
curl -X POST https://demo-node.example/api/v1/query \
-H "Authorization: Bearer $TOKEN" \
-H "Content-Type: application/json" \
-d '{"sql":"SELECT node_id, metric, value, units, recorded_at_ms FROM iot_reading ORDER BY recorded_at_ms DESC LIMIT 2000"}'